After every tremor felt in Dhaka, the same question fills family chats and office corridors: would our building survive a big one? The honest answer is that nobody can tell by looking at a building from the street. Earthquake safety depends on things hidden inside the concrete: the strength of the material, the size and spacing of the bars, how the foundations were built.
But the warning signs that matter most are visible to anyone. Engineers around the world use quick visual screening to decide which buildings need a closer look, and the same logic works for an owner or a tenant. This checklist gives you fifteen checks you can make in about an hour, explains what each one means, and tells you when to call an engineer.
Part 1: What you can find out without leaving your desk
Start with the building's history. Ask the owner, the developer, the flat owners' association or the people who have lived there longest.
- 1. When was it built? Buildings designed before the 1993 code had no national seismic requirements; those designed to BNBC 1993 were designed for lower forces than BNBC 2020 requires. A building designed after 2020 by a qualified engineer has the most demanding standard behind it.
- 2. Who designed it, and are there structural drawings? A building designed by a registered structural engineer, with drawings and calculations that still exist, is far easier to evaluate and usually far better detailed than one built from a mason's experience.
- 3. Was it approved, and for how many floors? Compare the approved number of storeys with what stands today. A difference is the single most common serious finding in Dhaka.
- 4. Has its use changed? A residential building now holding offices, a school, a garment unit or a warehouse carries more load, and possibly more people, than it was designed for.
- 5. What is the ground like? Was the plot a pond, a low-lying field or a filled area? Soft or filled ground can amplify shaking and, in the worst cases, lose strength in an earthquake.
Five warning signs you can see from the street
Tap each sign to see where it shows on a typical building and why engineers worry about it.
Part 2: What you can see from outside
Walk around the building and look at it from across the street. Take photos as you go; they will help an engineer later.
- 6. Is the ground floor open? Parking, shops or a lobby with few walls, below floors filled with brick walls, is the classic soft storey. In earthquakes worldwide it is the most common reason for collapse of concrete buildings.
- 7. Do the upper floors overhang the ground floor? Many Dhaka buildings extend each floor beyond the plot line on cantilevered beams. Heavy overhangs, especially with brick walls on them, add weight far from the columns and make the building more vulnerable.
- 8. Does the building touch its neighbours? Buildings built wall to wall, with floors at different heights, can hammer against each other in an earthquake, and a neighbour's floor slab can strike your columns mid-height. This is called pounding.
- 9. Is the shape irregular? L, T or U shaped plans, a tall part beside a short part, or a floor much bigger than the one below, can twist the building or concentrate damage where the parts meet.
- 10. Is there heavy weight on the roof? Large concrete water tanks, roof gardens with deep soil, extra rooms built on the roof or telecom towers add weight at the worst place: the top, where the shaking is strongest.

Part 3: What you can see inside
- 11. How big are the ground-floor columns? In a building of six storeys or more, very slender columns, for example 250 mm (10 inches) on one side, are a warning sign. Size alone does not prove anything, but it is an easy thing to note and photograph with a tape for scale.
- 12. Are there short columns? Look for columns with a low wall built up to window height on one side, or a mezzanine or staircase landing connected half-way up. The short exposed part attracts large forces and can fail suddenly in shear.
- 13. Is the concrete deteriorating? Rust stains, cracks along the line of bars, concrete that has fallen off to expose steel, or patches that sound hollow when tapped. Corrosion reduces the strength of exactly the bars an earthquake relies on. See our guide to which cracks are dangerous.
- 14. Have columns or walls been cut? Openings broken through walls, columns notched for pipes, beams cut for air-conditioning ducts, or walls removed to make larger shops are common alterations that the original design never anticipated.
- 15. Is there visible damage from past tremors? Diagonal cracks in walls between windows, cracks at the tops of columns, or gaps between the building and the neighbouring one that have widened.
What the warning signs mean
Each sign points to one of a few ways buildings fail in earthquakes. Knowing which helps you describe the concern to an engineer, and shows why some signs carry more weight than others.
| Warning sign | What it can lead to | Weight |
|---|---|---|
| Open ground floor (soft storey) | Damage concentrates in one storey; its columns fail and the floors above come down | Very high |
| Floors added beyond the design | More weight, larger earthquake forces, columns and foundations already near their limit | Very high |
| Short columns | Sudden shear failure with little warning | High |
| Slender columns, few ties | Columns crush and bars buckle; little ductility | High |
| Corroded bars, weak concrete | Less strength than the design assumed | High |
| Heavy overhangs and roof loads | Extra weight in the worst places | Medium |
| Pounding against neighbours | Local damage to columns struck by a neighbour's slab | Medium |
| Irregular shape | Twisting and damage where wings meet | Medium |
| Soft or filled ground | Amplified shaking; settlement or, rarely, liquefaction | Medium to high |
Things you can fix this month, at low cost
Not every improvement needs an engineer or a large budget. Many injuries in earthquakes are caused by things that fall, not by buildings collapsing. These steps are worth doing whatever the checklist shows:
- Secure tall furniture, such as wardrobes, bookshelves and almirahs, to the wall with brackets, and keep heavy items on low shelves.
- Check parapets, boundary walls and rooftop brick structures. Unreinforced brick parapets fall easily into the street. Ask a mason to tie or lower loose ones.
- Lighten the roof: remove unused tanks, debris, broken furniture and old construction material.
- Know where to shut off gas and electricity, and make sure gas cylinders are chained upright.
- Keep stairs and exits clear. Stored goods on staircases are a common problem in mixed-use buildings.
- Agree a family or office plan: where to take cover (under a sturdy table, away from glass), how to leave once the shaking stops, and where to meet.
When to call an engineer, and what happens next
If several warning signs apply, the next step is a seismic evaluation by a structural engineer. It usually happens in two stages:
- Screening visit. An engineer walks the building, reviews any drawings, measures the key members, notes the warning signs and gives an opinion on whether a detailed evaluation is needed. For many buildings this is enough to set priorities.
- Detailed evaluation. Where the screening finds real concerns, a Detailed Engineering Assessment measures the actual building: concrete cores, a rebar scanner to see the bars and ties, a survey of every floor, and a three-dimensional analysis against the earthquake forces that BNBC 2020 requires for the site.
The result is a clear answer: which parts of the building fall short, by how much, and the options to fix them, with costs. In many cases the fix is targeted, for example new walls or steel bracing in a few bays of the ground floor, and residents or businesses can stay in the building while the work is done.
For tenants and flat buyers
If you rent or are about to buy a flat, you cannot commission strengthening on your own, but you can ask the right questions. Ask the owner or developer for the approved drawings and the number of approved floors, ask whether a structural engineer supervised construction, and look for the warning signs in Parts 2 and 3. A flat owners' association can commission an evaluation for the whole building; the cost per flat is usually small compared with the value at stake.
The bottom line
You cannot see earthquake safety, but you can see the warning signs. An open ground floor, floors added later, short or slender columns, rusting bars and heavy weight on the roof are the ones that matter most. If your building shows several of them, an engineering evaluation is the responsible next step. Most buildings that fall short can be strengthened, and the time to do it is before the next big earthquake, not after it.
Topics:earthquakebuilding safetychecklistseismic evaluationDhaka
Frequently asked questions
Can a building be declared earthquake proof?
No building is earthquake proof. Codes such as BNBC 2020 aim for buildings that may be damaged in a rare, strong earthquake but do not collapse, so people can get out. An engineer can tell you whether a building meets that aim and what it would take to get there.
My building has RAJUK approval. Is it earthquake safe?
Approval shows the drawings were submitted and accepted. It does not show that the building was built as drawn, that the concrete reached its specified strength, or that floors were not added later. Approval is a good sign, not a guarantee.
Is a newer building always safer?
Usually a building designed after BNBC 2020 by a qualified engineer and properly supervised is designed for larger earthquake forces than an older one. But age is not the only factor: a well-built 1990s building can perform better than a poorly built new one.
How much does a seismic evaluation cost in Bangladesh?
It depends on the size of the building, how much testing is needed and whether drawings exist. A first screening visit costs far less than a full Detailed Engineering Assessment with cores and analysis. Contact us with the floor area, number of storeys and any drawings and we will give a fixed quote.
About Muhammad Sarowar Hossain
Founder & CEO, Prime Base Engineering, B.Sc. in Civil Engineering, PGDSCM-ISCEA. Muhammad Sarowar Hossain founded Prime Base Engineering and leads its structural assessment, retrofitting and construction work. He has worked on structural retrofitting of factories and industrial buildings across Bangladesh since 2017.