Skip to content

Compliance & Engineering Methodology

How we engineer, and the codes and standards you can hold us to.

Codes and standards

CodeWhat we use it for
BNBC 2020Loads, seismic zoning, wind, materials and detailing for every structure in Bangladesh
ACI 318Reinforced concrete design and seismic detailing
ACI 562Assessment, repair and rehabilitation of existing concrete structures
ACI 440.2RDesign of externally bonded FRP (CFRP) strengthening
AISC 360 and 341Structural steel design and seismic provisions
ASCE 41Seismic evaluation and retrofit methods for existing buildings
ASTM C42, C805, C597, C876Concrete cores, rebound hammer, pulse velocity, half-cell potential
RSC / Accord practiceStructural assessment and remediation methodology for RMG factories

Four disciplines on every project

  1. Investigate first. Soil investigation, site survey and, for existing buildings, material testing before any member is sized.
  2. Design to code, check independently. Analysis and design by one engineer, independent check by a second.
  3. Control quality on site. Mill certificates, cylinder and rebar tests, inspection checklists and hold points at critical stages.
  4. Document everything. Design basis report, calculations, test results and as-built drawings, handed over to the owner.

The retrofitting process

  1. Detailed Engineering Assessment and NDT — what the structure really is.
  2. Structural design and load analysis — what it must carry, and the options.
  3. Jacketing, CFRP and steel strengthening — phased works with QA/QC.
  4. Final safety certification — verification and records.

Tell us about the building.

Send drawings, photographs or earlier reports. An engineer will reply with what investigation is needed and a proposal.

Call