Earthquake building safety in Dhaka and Bangladesh: inspection, assessment and retrofitting
Most buildings in Dhaka were never checked against today's earthquake code. Here is how to tell which warning signs matter, what to do after a tremor, and how an engineer confirms whether a building is safe or needs strengthening.
A building is earthquake-safe when its columns, beams, walls and foundations can carry the forces of a design-level earthquake for its location, as set by BNBC 2020, without collapsing. Most buildings in Bangladesh built before 2020, and many built since, have never been checked against that standard. The only reliable way to know is an engineering assessment; the signs below tell you how urgently you need one.
What the November 2025 earthquake showed
On 21 November 2025 an earthquake of magnitude 5.7 (Bangladesh Meteorological Department) struck near Madhabdi in Narsingdi, about 25 km from Dhaka. It killed at least ten people. RAJUK reported that at least 50 buildings in Dhaka tilted or developed major cracks, sealed several of them, and asked for Detailed Engineering Assessments of the riskiest ones. It was a moderate earthquake by global standards. A larger one on the faults around Bangladesh would shake the same buildings much harder.
The damage followed a familiar pattern: open ground floors used for parking or shops, buildings that had gained floors without a capacity check, columns too small or too lightly reinforced, and buildings on soft or filled ground.
Warning signs: what to look for
Walk through the building, including the ground floor, stairs and roof. Photograph anything you find with a date.
Stop using the area and call an engineer the same day
- Diagonal or X-shaped cracks in a column or a beam
- Cracks where beams meet columns, or concrete that has broken away to show bent or exposed bars
- A visible tilt, doors and windows that suddenly jam, or a gap opening between the building and its neighbour
- Floors or stairs that have dropped, sagged or separated from walls
Arrange an inspection within days
- New cracks in brick infill walls, especially diagonal ones from window and door corners
- Cracks in the ground-floor slab or around column bases
- Rust stains or bulging concrete on columns, which point to corroded reinforcement that has weakened the column
Usually cosmetic, but record and watch
- Hairline cracks in plaster only, that do not grow
- Cracks at the joint between a brick wall and a column or beam
Buildings most at risk
- Soft-storey buildings: an open ground floor of parking or shops under floors with walls. The movement concentrates in that storey.
- Extended buildings: floors added without checking the columns and foundations below.
- Short columns: columns partly restrained by walls or windows, which attract large forces.
- Buildings on filled land: soft or recently filled ground amplifies shaking and can settle.
- Older buildings with poor concrete or corroded bars, and buildings whose use has changed, for example homes turned into garment units or warehouses.
What to do after an earthquake
- Get everyone out calmly if you see any sign from the first list above. Do not re-enter until an engineer has looked.
- Photograph cracks from a distance and close up, with a coin or a pen for scale.
- Check gas lines and electrical boards for damage before using them.
- Tell your neighbours and the building's owners' association: damage in one building can affect the next.
- Book an engineering inspection. If RAJUK or another authority has issued a notice for your building, the assessment it asks for is usually a Detailed Engineering Assessment.
How an engineer checks a building
Visual assessment (one visit). An engineer inspects every floor, maps the cracks and the structural system, measures key members and identifies obvious problems. The result is a clear answer: safe to use, use with restrictions, or not safe until investigated further.
Detailed Engineering Assessment (DEA). Where the visual check raises doubts, the building is measured and tested: concrete cores, rebound hammer and ultrasonic tests, reinforcement scanning, soil information, and a full structural analysis against BNBC 2020. The DEA tells you exactly which members are weak and what the building can carry. Read what a DEA involves, or see our DEA service.
How weak buildings are strengthened
Most buildings can be made much safer without demolition. The method follows from the assessment:
- Column jacketing with reinforced concrete, steel or CFRP, to give weak columns more strength and ductility
- New shear walls or steel bracing, often in the ground floor, to stop soft-storey failure
- Foundation strengthening where the foundations cannot carry the extra forces
- Reducing load, for example removing illegal additions or heavy rooftop tanks
Work can often be done floor by floor while the building stays occupied. See seismic retrofitting and how to choose a retrofitting company.
What it costs
The cost of an assessment depends mainly on the floor area, the number of storeys and how much testing is needed. The cost of strengthening depends on how many members need work and the method chosen. A visual assessment costs a small fraction of a DEA, and a DEA a small fraction of the strengthening it may prevent from being wrong. Send us the floor area, number of storeys and a few photographs for a written quotation.
Questions owners ask
How do I know if my building is earthquake-safe?
Only an engineering assessment can confirm it: a visual inspection first, then a Detailed Engineering Assessment with testing and analysis against BNBC 2020 if the inspection raises doubts. Warning signs such as diagonal cracks in columns, a tilt or an open ground floor tell you how urgently you need one.
My building tilted or cracked after the earthquake. What should I do?
If you see diagonal cracks in columns or beams, cracks at beam-column joints or a visible tilt, move people out and do not re-enter until an engineer has inspected the building. Photograph the damage and book an inspection the same day.
Which seismic zone is Dhaka in?
Dhaka is in Zone 2 under BNBC 2020. Parts of the north and east of Bangladesh are in higher zones. The soil on your plot also changes the design forces, so the zone alone does not decide whether a building is safe.
Can an old building be made earthquake-resistant?
In most cases yes. Column jacketing, new shear walls or steel bracing, and foundation strengthening can bring an existing building much closer to current code requirements, usually without demolition and often while it stays in use.
How long does an earthquake safety assessment take?
A visual assessment usually takes one site visit and a short report within days. A Detailed Engineering Assessment typically takes several weeks, depending on the building's size, the testing needed and access to drawings.
Does RAJUK require an assessment of my building?
RAJUK has issued notices to buildings it considers risky and asked for Detailed Engineering Assessments of them. If your building has received a notice, follow its instructions; we can carry out the assessment it asks for.
Tell us about the building.
Send drawings, photographs or earlier reports. An engineer will reply with what investigation is needed and a proposal.